Product manual
Two working modes are available: culture mode and absorbance test mode:
1. Cultivation mode: Provide the environment required for microbial growth, and at the same time detect and record the absorbance of the sample at a specified wavelength.
2. Absorbance test mode: Full-spectrum absorbance test can be performed on the specified sample, and absorbance values at different wavelengths are given.
Performance characteristics
- Using advanced full-spectrum detection technology, no need to replace the filter, it can detect 300~850 range at the same time
- Absorbance at any wavelength within the range, providing a solution for a variety of biomass quantitative detection.
- The highest shaking speed can reach 1250rpm, so that the liquid in a small volume can be fully mixed,
- It can realize shaking culture of microorganisms in 96-well plate.
- With two culture plate positions, a variety of adapters are compatible with culture plates of different specifications, and the maximum
- 192 samples are processed at a time.
- As a light source, xenon lamp has the advantages of high energy and no need for preheating. It is a high-resolution, high-sensitivity,
- Rapid detection lays the foundation, and the light source has good stability and long life, and does not need to be replaced frequently.
- The optimized algorithm removes background noise and obtains a more accurate growth curve.
- With RGBW four-color light setting function, it can be used to study the influence of light factors such as light cycle, light wavelength and light intensity on the growth of algae.
- It has a hot cover anti-condensation design, with cooling and heating modules, and the temperature control range is 15-60°C at room temperature (25°C). The temperature can be changed in the middle of microbial culture to facilitate the accumulation of specific metabolites.
- With standard preset program, simple operation and convenient data processing. At the same time, it supports customer-defined templates for personalized operation settings and data analysis.
Instrument parameters
1. Model: MGC-200
2. Dimensions: 510*655*350mm
3. Detection wavelength: 300-850nm
4. Microbial culture container: Cell culture plate/ELISA plate
5. Number of channels: 2 board positions, up to 192 channels
6. Medium volume limit: 2.5ml
7. Light source: Xenon lamp
8. Temperature range: 15-60°C (at room temperature 25°C)
9. Shaking speed: 200-1250 rpm
10. Detection method: Single hole multi-point detection
11. Absorbance range: Highest value 8.0 OD
12. Detection interval: 5-360 minutes can be set
13. Longest incubation time: 1600 hours
14. Authority management: Separate user and administrator privileges
15. Operation failure alarm: Yes
16. Sterilization module: UV sterilization
17. Full spectrum scan: Yes
18. Thermal Lid Anti-Condensation: Yes
19. Humidity monitoring: Yes
20. Mid-way temperature change function: Yes
21. Reference channel selection: Yes