Desktop High-Speed Refrigerated Centrifuge Model HSC-2015L Main technical

Short Description:

The main technical parameters

  • 1. Maximum rotor capacity: 24×1.5/2.0mL centrifuge tube
  • 2. Maximum relative centrifugal force: 21.400xg (15000rpm)
  • 3. Temperature control range: -10°C to 40°C
  • 4. Speed: 500-15000 in increments of 100rpm
  • 5. Centrifugal timing: 1 second – 99 minutes 59 seconds
  • 6. Maximum power/rated power: 1000W/500W
  • 7. Dimensions (length X width X height): 385x608x318(mm)
  • 8. Noise≤58dB

Product Detail

features

1. The machine is equipped with a variety of rotors; standard: 24*1.5/2.0ml centrifuge tubes, optional: 12*5ml centrifuge tubes, 4*PCR 8-row tubes
2. There are no less than 2 types of optional rotors for each specification; support for optional airtight rotors
3. The rotor and rotor cover can be autoclaved (121°C, 20 minutes), and are easy to disassemble and clean
4. The airtight rotor and rotor cover can be sterilized at 134°C to remove prions
5. The airtight rotor can be removed as a whole and placed in a biological safety cabinet to improve the safety of the experiment
6. The maximum speed of each specification rotor reaches 15,000rpm
7. 5-inch LCD screen, simultaneously displaying speed, relative centrifugal force, time, temperature and motor running status, etc.
8. The working parameters can be freely programmed and called
9. The lifting speed can be selected according to the sample requirements, and the fastest time is <15s
10. With Soft brake function, preventing resuspension and protecting sensitive samples
11. Speed (rpm), relative centrifugal force (×g) can be input by the user, and the parameter value can be changed during the centrifugation process
12. The speed can be set from 500rpm to the highest speed, increasing by 100rpm
13. Constant speed timing function (timing range: 1s-99min59s); jog means instant centrifugal
14. Equipped with a fault self-diagnosis system (failures such as stall, over-temperature, self-locking of the door cover, etc.), and the interface prompts at the same time
15. Equipped with emergency device, the door cover of the instrument can also be opened in case of power failure
16. Driven by imported frequency conversion motor and controlled by microcomputer
17. Imported high-performance compressors and fluorine-free environmentally friendly refrigerants are used
18. The temperature control range is -10 to 40°C; even at the highest speed @15000rpm, the temperature remains stable at 4°C
19. The cooling speed is fast, and it can drop from room temperature to 4°C within <6 minutes
20. With static and dynamic dual pre-cooling functions
21. The centrifugal cavity has good corrosion resistance after special process, durable and more beautiful
22. Have the medical device record, and can provide the record information certificate (Zhe Yong Ji Bei No. 20200088)